Under arm crutches
also know as broken leg crutches, made from standard aluminum adjustable crutches
most frequency used by removing weight from a single leg, provide stability to continue walking.
Under Arm Crutches
also know as broken leg crutches, made from standard aluminum adjustable crutches
most frequency used by removing weight from a single leg, provide stability to continue walking.
Adjustable in height Strong Aluminum Material Sponge Handle
KSh 1,800.00 KSh 2,000.00
Under arm crutches
also know as broken leg crutches, made from standard aluminum adjustable crutches
most frequency used by removing weight from a single leg, provide stability to continue walking.
Also known as a stoma bag which is used to collect waste from the body during procedure known as colostomy.
The opening is usually formed between the large intestine (colon) and the abdominal wall
Can be reused more than one time.
Diameter of up to 60mm.
Autoclaves use steam heat to kill any microbial life that may be present on a contaminated load. considered sterile once it has undergone a full sterilization cycle. Once a load is sterile, it can be used without fear of introducing foreign microorganisms into a sensitive environment, such as a laboratory, hospital operating room, food production facility, and so on.
In order to kill a cell with heat, its temperature must be raised to a degree at which the proteins in the cell wall break down and coagulate. Steam is a very efficient medium for heat transference, which makes it an excellent way to destroy microbes. Air, on the other hand, is a very inefficient way to transfer heat/energy because of a concept known as the heat of vaporization.
That energy is what makes steam so much more efficient at destroying microorganisms. When steam encounters a cooler object, it condenses into water. Then, it transfers all of the energy that was used to boil the water directly into the water. This process heats up the cells far more efficiently than air at similar temperatures. This is why we use steam to achieve sterility.
Sterilization cycle
1. Purge Phase: Steam flows through the sterilizer and starts to displace the air; temperature and pressure ramp slightly to a continuous flow purge.
2. Exposure (Sterilization) Phase: During this phase, the autoclave’s control system is programmed to close the exhaust valve, thereby causing the interior temperature and pressure to increase to the desired setpoint. The program then maintains the desired temperature (dwells) until the desired time is reached.
3. Exhaust Phase: Pressure is released from the chamber through an exhaust valve and the interior is restored to an ambient pressure (though contents remain relatively hot).
silicone is effective at both preventing and healing scars,
It works by creating a protective layer over the scar to stop it losing water, damaged skin needs moisture to heal as dry skin tiny cracks at can allow bacteria to enter.
It can slow down healing by causing further inflammation
It is one big sheet that is cut according to the size of the scar, then place the sheet on top of the scar, after some time the scar will vanish
Suction Machine is an appliance used to remove substances such as blood, saliva, mucus and vomit from a person’s airway.
Working Principle
It works by atmospheric pressure, when the piston is raised creating a partial vacuum, atmospheric pressure outside forces water into the cylinder hence it is permitted to escape by an outlet valve.
Oil free lubrication pump to keep the environment from being polluted by the oil mist.
low noise
Square negative pressure meter and plastic cover.
no any negative pressure to be generated during running to ensure reliable and safe operation.
Negative pressure regulating system can be adjusted steplessly small in size, light in weight and portable