Gauze Drum
Cylindrical containers used to sterilize dressing material in a sterilizer
It helps
Gauze Drum
Cylindrical containers used to sterilize dressing material in a sterilizer
It helps
Infrared heating lamp with stand
IR lamp is a high quality heat lamp designed to provide localized heat treatment.
Manage pain and injury effectively heat therapy provides benefits for numerous injuries, illness and chronic conditions.
The heat lamp uses short-wave infrared light produced by an incandescent heat sources to give a deeper penetration of heat than conventional heat sources.
This can enhance blood circulation improving the transport rate of essential biochemical compounds as well as provide pain relief and a pleasant warming effective exposure.
Heat therapy for home or business it is ideal for us at home or in a professional setting.
Autoclaves use steam heat to kill any microbial life that may be present on a contaminated load. considered sterile once it has undergone a full sterilization cycle. Once a load is sterile, it can be used without fear of introducing foreign microorganisms into a sensitive environment, such as a laboratory, hospital operating room, food production facility, and so on.
In order to kill a cell with heat, its temperature must be raised to a degree at which the proteins in the cell wall break down and coagulate. Steam is a very efficient medium for heat transference, which makes it an excellent way to destroy microbes. Air, on the other hand, is a very inefficient way to transfer heat/energy because of a concept known as the heat of vaporization.
That energy is what makes steam so much more efficient at destroying microorganisms. When steam encounters a cooler object, it condenses into water. Then, it transfers all of the energy that was used to boil the water directly into the water. This process heats up the cells far more efficiently than air at similar temperatures. This is why we use steam to achieve sterility.
Sterilization cycle
1. Purge Phase: Steam flows through the sterilizer and starts to displace the air; temperature and pressure ramp slightly to a continuous flow purge.
2. Exposure (Sterilization) Phase: During this phase, the autoclave’s control system is programmed to close the exhaust valve, thereby causing the interior temperature and pressure to increase to the desired setpoint. The program then maintains the desired temperature (dwells) until the desired time is reached.
3. Exhaust Phase: Pressure is released from the chamber through an exhaust valve and the interior is restored to an ambient pressure (though contents remain relatively hot).
MANUAL BABY WEIGHING SCALE
It is used to measure infant’s weight by placing the infant on the tray and reading the weight on the gauge.
It can hold up CAP 20kg and grad 100g.
It comes with a tray to hold the infant.
Durable and affordable.