0 out of 5(0)How to Use a Fetal Doppler: Steps
- Before you use your doppler, consider that some women report hearing the heartbeat easier in the morning since that’s when the belly is typically the least bloated. Using the doppler while you have a full bladder can also make the heartbeat easier to hear.
- To start, lie with your back down on a flat surface. Expose your abdomen like you would during a regular ultrasound.
- Apply a blob of ultrasound gel or other lubricant to your lower belly. Since the gel will reduce static, use a generous amount.
- Place the doppler probe in the gel and turn the device on.
- Starting from your pubic bone, gently glide the probe upwards towards your belly button. Slowly rock the probe, covering every part of your stomach so that you find the fetus.
- If you hear a heart beat in your earphones and the display shows a heart beat per minute (BPM) of about 120 or higher, you’ve likely found your fetus. Some women say the sound is similar to galloping horses.
- If after a few minutes you cannot find your baby, shut the device off and try another time. You may need to wait for the baby to grow bigger or switch positions.
- After you’re finished, clean off the probe to avoid build up. You may choose to wipe it with 70% ethanol and let air dry or simply wipe it with a clean, dry cloth. Do not submerge the device in water (except waterproof models) or apply cleaning chemicals.
SKU: n/aKSh 10,000.00 -
Christmas Offer, Home Care Equipment, MEDICAL EQUIPMENT
Ripple Mattress/Air Mattress
0 out of 5(0)A ripple mattress is a special mattress type of mattress that works by inflating air in the cells and alternating the air to each and every cell in the mattress.
The bed-type medical air cushion is composed with two parts: main frame and air cushion. The air cushion has two separate ballonet. Under the control of the main frame every ballonet can touch a different part of the body every six minutes. the fluctuation ballonet can expedite blood circulating to avoid the appearance of the bedsore on the patients who stay in bed for long. so that to cure the bedsore quickly or prevent the sore all together.
Bedsores properly known as pressure ulcers are caused by many factors such as unrelieved pressure, friction, humidity, temperature and medication.
bedsores are fatal however we can prevent it from happening by using a ripple mattress.
SKU: n/aKSh 8,500.00KSh 11,500.00 -
Uncategorized, Black Friday, Christmas Offer, Home Care Equipment, OPERATING THEATRE EQUIPMENT
Oxygen Concentrator Kenya
Uncategorized, Black Friday, Christmas Offer, Home Care Equipment, OPERATING THEATRE EQUIPMENTOxygen Concentrator Kenya
0 out of 5(0)Oxygen concentrator single flow it is an equipment that concentrate the air from the environment purifies it and gives pure oxygen to the patient.
Oxygen purity output 90-95% at all flow levels
Power consumption is 400W
Dimension: Height 24.50 inch
Width: 19.60 inch
Depth: 15.30 inch
SKU: n/aKSh 70,000.00 -
Home Care Equipment
Mercurial blood pressure machine
0 out of 5(0)Mercurial blood pressure machine
A device used to measure blood pressure.
How it works;
After cuffing the patient pump using a bulb until the pressure is about 20mmHg above the expected systolic blood pressure.
The patient should be comfortable and relaxed the lower arm should be placed at the level of the heart with the inside of the arm facing upwards
Place the chest piece of the stethoscope on the artery under the cuff.
To be able to measure open the air release screw on the bulb by turning it counter clockwise, ideally the rate of air release should be 2-3mm, perform a visual check of the air release rate by looking at scale. Mercury display must move along the scale at a speed of 1-15 graduations per second.
Once the upper blood pressure value has been reached a rhythmic thumbing sound is heard
Systolic blood pressure value is the pressure measured when the heart contracts forcing blood into the blood vessels
When the diastolic pressure is reached the thumbing sounds stops
Diastolic is the pressure measured when the cardiac muscle is expanded and fills up with blood again.
Open the air release valve completely so that air can escape from the cuff immediately and the procedure has been completed.
SKU: n/aKSh 3,000.00