E.N.T Diagnostic set
ENT is a device that is used to examine Ear, Nose and Throat
it consist of: Ophthalmoscope and otoscope and battery handle.
A diagnostic set consist of an ophthalmoscope for examining the eye, an otoscope for examining the tympanic membrane and external ear canal and a battery handle to power these instrument
a complete ENT examination includes: inspection of the face, ears, nose, throat and neck
KSh 8,500.00
CompareE.N.T Diagnostic set
ENT is a device that is used to examine Ear, Nose and Throat
it consist of: Ophthalmoscope and otoscope and battery handle.
High resolution 15 inch big screen medical ICU patient monitor with 6 parameter, it is used to monitor vital sign for a patient.
Has 6 parameter,
ECG- It records electrical signal from the heart to check different heart conditions.
Respiration: monitor blood gases both arterial and venous, monitoring of brain and organ oxygenation and perfusion and hemodynamics.
Temperature: It records the body temperature and saves the information.
NIBP: It measures systolic and diastolic and mean arterial blood pressure values and heart rate.
SPO2: Measures oxygen saturation in the body.
Pulse Rate/ Heart Rate: The number of heart beats per minute
Pulse oximetry is a noninvasive method for monitoring a person’s oxygen saturation. Though its reading of peripheral oxygen saturation (SpO2) is not always identical to the more desirable reading of arterial oxygen saturation (SaO2) from arterial blood gas analysis, the two are correlated well enough that the safe, convenient, noninvasive, inexpensive pulse oximetry method is valuable for measuring oxygen saturation in clinical use.
In its most common (transmissive) application mode, a sensor device is placed on a thin part of the patient’s body, usually a fingertip or earlobe, or in the case of an infant, across a foot. The device passes two wavelengths of light through the body part to a photodetector. It measures the changing absorbance at each of the wavelengths, allowing it to determine the absorbances due to the pulsing arterial blood alone, excluding venous blood, skin, bone, muscle, fat, and (in most cases) nail polish.
Reflectance pulse oximetry is a less common alternative to transmissive pulse oximetry. This method does not require a thin section of the person’s body and is therefore well suited to a universal application such as the feet, forehead, and chest, but it also has some limitations. Vasodilation and pooling of venous blood in the head due to compromised venous return to the heart can cause a combination of arterial and venous pulsations in the forehead region and lead to spurious SpO2 results. Such conditions occur while undergoing anesthesia with endotracheal intubation and mechanical ventilation or in patients in the Trendelenburg position.
Suction Machine is an appliance used to remove substances such as blood, saliva, mucus and vomit from a person’s airway.
Working Principle
It works by atmospheric pressure, when the piston is raised creating a partial vacuum, atmospheric pressure outside forces water into the cylinder hence it is permitted to escape by an outlet valve.
Oil free lubrication pump to keep the environment from being polluted by the oil mist.
low noise
Square negative pressure meter and plastic cover.
no any negative pressure to be generated during running to ensure reliable and safe operation.
Negative pressure regulating system can be adjusted steplessly small in size, light in weight and portable