Digital Thermometer,
It is a medical equipment that measures body temperature,
It has a flexible tip
Can record both high and low temp
Digital Thermometer,
It is a medical equipment that measures body temperature,
It has a flexible tip
Can record both high and low temp
A ripple mattress is a special mattress type of mattress that works by inflating air in the cells and alternating the air to each and every cell in the mattress.
The bed-type medical air cushion is composed with two parts: main frame and air cushion. The air cushion has two separate ballonet. Under the control of the main frame every ballonet can touch a different part of the body every six minutes. the fluctuation ballonet can expedite blood circulating to avoid the appearance of the bedsore on the patients who stay in bed for long. so that to cure the bedsore quickly or prevent the sore all together.
Bedsores properly known as pressure ulcers are caused by many factors such as unrelieved pressure, friction, humidity, temperature and medication.
bedsores are fatal however we can prevent it from happening by using a ripple mattress.
Autoclaves use steam heat to kill any microbial life that may be present on a contaminated load. considered sterile once it has undergone a full sterilization cycle. Once a load is sterile, it can be used without fear of introducing foreign microorganisms into a sensitive environment, such as a laboratory, hospital operating room, food production facility, and so on.
In order to kill a cell with heat, its temperature must be raised to a degree at which the proteins in the cell wall break down and coagulate. Steam is a very efficient medium for heat transference, which makes it an excellent way to destroy microbes. Air, on the other hand, is a very inefficient way to transfer heat/energy because of a concept known as the heat of vaporization.
That energy is what makes steam so much more efficient at destroying microorganisms. When steam encounters a cooler object, it condenses into water. Then, it transfers all of the energy that was used to boil the water directly into the water. This process heats up the cells far more efficiently than air at similar temperatures. This is why we use steam to achieve sterility.
Sterilization cycle
1. Purge Phase: Steam flows through the sterilizer and starts to displace the air; temperature and pressure ramp slightly to a continuous flow purge.
2. Exposure (Sterilization) Phase: During this phase, the autoclave’s control system is programmed to close the exhaust valve, thereby causing the interior temperature and pressure to increase to the desired setpoint. The program then maintains the desired temperature (dwells) until the desired time is reached.
3. Exhaust Phase: Pressure is released from the chamber through an exhaust valve and the interior is restored to an ambient pressure (though contents remain relatively hot).
High resolution 15 inch big screen medical ICU patient monitor with 6 parameter, it is used to monitor vital sign for a patient.
Has 6 parameter,
ECG- It records electrical signal from the heart to check different heart conditions.
Respiration: monitor blood gases both arterial and venous, monitoring of brain and organ oxygenation and perfusion and hemodynamics.
Temperature: It records the body temperature and saves the information.
NIBP: It measures systolic and diastolic and mean arterial blood pressure values and heart rate.
SPO2: Measures oxygen saturation in the body.
Pulse Rate/ Heart Rate: The number of heart beats per minute