Read more about this product https://alphasurgicals.co.ke/3m-littmann-classic-ii-s-e-stethoscope/
Littmann Stethoscope
KSh 4,500.00 KSh 6,500.00
Related products
-
MEDICAL EQUIPMENT, OPERATING THEATRE EQUIPMENT, SUCTION MACHINES
SUCTION MACHINE- KENYA
0 out of 5(0)Suction Machine is an appliance used to remove substances such as blood, saliva, mucus and vomit from a person’s airway.
Working Principle
It works by atmospheric pressure, when the piston is raised creating a partial vacuum, atmospheric pressure outside forces water into the cylinder hence it is permitted to escape by an outlet valve.
Oil free lubrication pump to keep the environment from being polluted by the oil mist.
low noise
Square negative pressure meter and plastic cover.
no any negative pressure to be generated during running to ensure reliable and safe operation.
Negative pressure regulating system can be adjusted steplessly small in size, light in weight and portable
SKU: n/aKSh 20,000.00 -
Christmas Offer, Home Care Equipment, MEDICAL EQUIPMENT
Ripple Mattress/Air Mattress
0 out of 5(0)A ripple mattress is a special mattress type of mattress that works by inflating air in the cells and alternating the air to each and every cell in the mattress.
The bed-type medical air cushion is composed with two parts: main frame and air cushion. The air cushion has two separate ballonet. Under the control of the main frame every ballonet can touch a different part of the body every six minutes. the fluctuation ballonet can expedite blood circulating to avoid the appearance of the bedsore on the patients who stay in bed for long. so that to cure the bedsore quickly or prevent the sore all together.
Bedsores properly known as pressure ulcers are caused by many factors such as unrelieved pressure, friction, humidity, temperature and medication.
bedsores are fatal however we can prevent it from happening by using a ripple mattress.
SKU: n/aKSh 8,500.00KSh 11,500.00 -
Black Friday, Christmas Offer, Home Care Equipment, MEDICAL EQUIPMENT
Fetal Doppler-Kenya
0 out of 5(0)How to Use a Fetal Doppler: Steps
- Before you use your doppler, consider that some women report hearing the heartbeat easier in the morning since that’s when the belly is typically the least bloated. Using the doppler while you have a full bladder can also make the heartbeat easier to hear.
- To start, lie with your back down on a flat surface. Expose your abdomen like you would during a regular ultrasound.
- Apply a blob of ultrasound gel or other lubricant to your lower belly. Since the gel will reduce static, use a generous amount.
- Place the doppler probe in the gel and turn the device on.
- Starting from your pubic bone, gently glide the probe upwards towards your belly button. Slowly rock the probe, covering every part of your stomach so that you find the fetus.
- If you hear a heart beat in your earphones and the display shows a heart beat per minute (BPM) of about 120 or higher, you’ve likely found your fetus. Some women say the sound is similar to galloping horses.
- If after a few minutes you cannot find your baby, shut the device off and try another time. You may need to wait for the baby to grow bigger or switch positions.
- After you’re finished, clean off the probe to avoid build up. You may choose to wipe it with 70% ethanol and let air dry or simply wipe it with a clean, dry cloth. Do not submerge the device in water (except waterproof models) or apply cleaning chemicals.
SKU: n/aKSh 10,000.00 -
Black Friday, LABORATORY EQUIPMENT AND CONSUMABLES, MEDICAL EQUIPMENT
Autoclave Kenya
0 out of 5(0)Autoclaves use steam heat to kill any microbial life that may be present on a contaminated load. considered sterile once it has undergone a full sterilization cycle. Once a load is sterile, it can be used without fear of introducing foreign microorganisms into a sensitive environment, such as a laboratory, hospital operating room, food production facility, and so on.
In order to kill a cell with heat, its temperature must be raised to a degree at which the proteins in the cell wall break down and coagulate. Steam is a very efficient medium for heat transference, which makes it an excellent way to destroy microbes. Air, on the other hand, is a very inefficient way to transfer heat/energy because of a concept known as the heat of vaporization.
That energy is what makes steam so much more efficient at destroying microorganisms. When steam encounters a cooler object, it condenses into water. Then, it transfers all of the energy that was used to boil the water directly into the water. This process heats up the cells far more efficiently than air at similar temperatures. This is why we use steam to achieve sterility.
Sterilization cycle
1. Purge Phase: Steam flows through the sterilizer and starts to displace the air; temperature and pressure ramp slightly to a continuous flow purge.
2. Exposure (Sterilization) Phase: During this phase, the autoclave’s control system is programmed to close the exhaust valve, thereby causing the interior temperature and pressure to increase to the desired setpoint. The program then maintains the desired temperature (dwells) until the desired time is reached.
3. Exhaust Phase: Pressure is released from the chamber through an exhaust valve and the interior is restored to an ambient pressure (though contents remain relatively hot).
SKU: n/aKSh 18,000.00