Manual Resuscitator
ambu bag or bag valve it is a handheld tool that is used to deliver oxygen
ambu bag or bag valve it is a handheld tool that is used to deliver oxygen
Self-inflating bag
One way valve
Mask
Oxygen reservoir
KSh 3,000.00
Compareambu bag or bag valve it is a handheld tool that is used to deliver oxygen
Principle of heat radiation
When the heater operates, the reflect cover of parabola type radiates evenly the infrared light emitted by the heat source to the baby mattress or the baby’s skin to achieve the purpose of heating.
Operating mode: The infant radiant warmer has a skin temperature mode control temperature system which automatically controls the output of heat radiation according to the temperature detected by the skin temperature sensor.
Main Function:
Radiator: provides infrared radiation for the infant
Tray: for placing low pressure aspirator and nursing articles max weight 2kg
Baby bed: to carry the baby safely max weight is 10kg, it can be tilted according to the need of the care giver
How an infusion pump works
Infusion is a method of putting fluids including drugs into the blood stream.
An infusion pump draws fluid from a standard bag of IV fluid and controls the rate of flow.
It provides accurate and continuous therapy, can use any size bag of IV
Fluids can be delivered at either very slow or fast rate
It is the most basic type of wheelchair, it is light, has a leather upholstery and easy to be folded.
It can hold a maximum weight of 100Kg.
Advantage with this wheelchair is it comfortable and super in expensive has solid wheels can last forever.
best quality with latest technology infused to bring comfort.
Mercurial blood pressure machine
A device used to measure blood pressure.
How it works;
After cuffing the patient pump using a bulb until the pressure is about 20mmHg above the expected systolic blood pressure.
The patient should be comfortable and relaxed the lower arm should be placed at the level of the heart with the inside of the arm facing upwards
Place the chest piece of the stethoscope on the artery under the cuff.
To be able to measure open the air release screw on the bulb by turning it counter clockwise, ideally the rate of air release should be 2-3mm, perform a visual check of the air release rate by looking at scale. Mercury display must move along the scale at a speed of 1-15 graduations per second.
Once the upper blood pressure value has been reached a rhythmic thumbing sound is heard
Systolic blood pressure value is the pressure measured when the heart contracts forcing blood into the blood vessels
When the diastolic pressure is reached the thumbing sounds stops
Diastolic is the pressure measured when the cardiac muscle is expanded and fills up with blood again.
Open the air release valve completely so that air can escape from the cuff immediately and the procedure has been completed.